                                    MOTOROLA

                                    FREEWARE

                             8-BIT CROSS ASSEMBLERS

                                  USER'S MANUAL




 






























                                     EDITED BY

                                   KEVIN ANDERSON

                             FIELD APPLICATIONS ENGINEER




 
                           TABLE OF CONTENTS

CHAPTER 1.........................................................  1

     1.1   INTRODUCTION ..........................................  1
     1.2   ASSEMBLY LANGUAGE .....................................  1
     1.3   OPERATING ENVIRONMENT .................................  2
     1.4   ASSEMBLER PROCESSING ..................................  2

CHAPTER 2 ........................................................  3

     2.1   INTRODUCTION ..........................................  3
     2.2   SOURCE STATEMENT FORMAT ...............................  3
          2.2.1   Label Field ....................................  3
          2.2.2   Operation Field ................................  4
          2.2.3   Operand Field ..................................  4
               2.2.3.1  M6800/6801 Operand Syntax ................  5
               2.2.3.2  M6800/M68HC04 Operand Syntax .............  5
               2.2.3.3  M6805/M68HC05 Operand Syntax .............  5
               2.2.3.4  M6809 Operand Syntax .....................  5
               2.2.3.5  M68HC11 Operand Syntax ...................  6
               2.2.3.6  Expressions ..............................  6
               2.2.3.7  Operators ................................  7
               2.2.3.8  Symbols ..................................  7
               2.2.3.9  Constants ................................  7
          2.2.4   Comment Field ..................................  8
     2.3   ASSEMBLER OUTPUT ......................................  9

CHAPTER 3 - RUNNING THE ASSEMBLERS ...............................  10

     3.1   ASSEMBLER INVOCATION ..................................  10
     3.2   ERROR MESSAGES ........................................  11

CHAPTER 4 - ASSEMBLER DIRECTIVES .................................  12

     4.1   INTRODUCTION ..........................................  12
     4.2   BSZ - BLOCK STORAGE OF ZEROS ..........................  12
     4.3   EQU - EQUATE SYMBOL TO A VALUE ........................  13
     4.4   FCB - FORM CONSTANT BYTE ..............................  13
     4.5   FCC - FORM CONSTANT CHARACTER STRING ..................  13
     4.6   FDB - FROM DOUBLE BYTE CONSTANT .......................  13
     4.7   FILL - FILL MEMORY ....................................  14
     4.8   OPT - ASSEMBLER OUTPUT OPTIONS ........................  14
     4.9   ORG - SET PROGRAM COUNTER TO ORIGIN ...................  14
     4.10   PAGE - TOP OF PAGE ...................................  15
     4.11   RMB - RESERVE MEMORY BYTES ...........................  15
     4.12   ZMB - ZERO MEMORY BYTES ..............................  15

APPENDIX A - CHARACTER SET .......................................  16

APPENDIX B - ADDRESSING MODES ....................................  18

     B.1   M6800/M6801 ADDRESSING MODES ..........................  18
     B.2   M6804/68HC04 ADDRESSING MODES .........................  19
     B.3   M6805/68HC05 ADDRESSING MODES .........................  21



                                i







                           TABLE OF CONTENTS

     B.4   M6809 ADDRESSING MODES ................................  22
     B.5   M68HC11 ADDRESSING MODES ..............................  26

APPENDIX C - DIRECTIVE SUMMARY ...................................  28

APPENDIX D - ASSEMBLER LISTING FORMAT ............................  29

APPENDIX E - S-RECORD INFORMATION ................................  30

     E.1   INTRODUCTION ..........................................  30
     E.2   S-RECORD CONTENT ......................................  30
     E.3   S-RECORD TYPES ........................................  30
     E.4   S-RECORD EXAMPLE ......................................  31

                                   ii





                               CHAPTER 1
                          GENERAL INFORMATION


1.1   INTRODUCTION

This is the user's reference manual for the  IBM-PC  hosted  Motorola 
Freeware  8  bit  cross  assemblers.   It  details  the  features and 
capabilities  of  the  cross   assemblers,   assembler   syntax   and 
directives,  options,  and  listings.  It  is  intended as a detailed
reference and an introduction  for  those  unfamiliar  with  Motorola 
assembler   syntax  and  format.   Those  experienced  with  Motorola 
assembler  products  may  wish  to  examine  the  file   ASSEMBLER.DOC 
available  with  the  cross  assemblers,  which briefly describes the 
differences  between  these  assemblers  and  earlier,  non-pc  based 
versions.

Assemblers are programs that process assembly language source program 
statements and translate them into executable machine language object 
files.   A programmer writes his source program using any text editor 
or word processor that can produce an ASCII text output.   With  some 
word  processors  this is known as "non document" mode.  Non document 
mode produces a  file  without  the  non-printable  embedded  control 
characters that are used in document formatting.  (Caution: assembling 
a file that has been formatted with embedded control  characters  may 
produce assembler errors.  The solution is to convert the source file 
to ASCII text.) Once the source code is written, the source  file  is 
assembled by processing the file via the assembler.

Cross  assemblers  (such  as  the Motorola Freeware Assemblers) allow 
source programs written and edited on  one  computer  (the  host)  to 
generate  executable  code  for  another  computer (the target).  The 
executable object file can then be downloaded and run on  the  target 
system.   In  this  case  the host is an IBM-PC or compatible and the 
target system is based on  a  Motorola  8-bit  microprocessor  (6800, 
6801, 6803, 6805, 68HC05, 6809, or 68HC11).

The  assemblers are the executable programs AS*.EXE where * is any of 
0, 1, 4, 5, 9, or  11  depending  on  which  microprocessor  you  are 
writing  code  for.   The details of executing the assembler programs 
are found in Chapter 3.  The assembly language format and syntax  for 
the  various processors is very similar with slight variations due to 
varied programming resources  (instructions,  addressing  modes,  and 
registers). These variations are explained in Appendix B.


1.2 ASSEMBLY LANGUAGE

The symbolic language used to code source programs to be processed by 
the  Assembler  is  called  assembly  language.  The  language  is  a 
collection   of  mnemonic  symbols  representing:  operations  (i.e., 
machine  instruction  mnemonics  or  directives  to  the  assembler), 
symbolic names, operators, and special symbols. The assembly language 
provides mnemonic operation codes for all machine instructions in the 
instruction  set.  The  instructions are defined and explained in the 
Programming Reference Manuals for  the  specific  devices,  available 
from Motorola. The assembly language also contains mnemonic directives



                                   Freeware Assemblers User's Manual


which  specify  auxiliary  actions  to be performed by the Assembler. 
These directives are not always translated into machine language.


1.3   OPERATING ENVIRONMENT

These assemblers will run on  any  IBM-PC,  XT,  AT,  PS-2,  or  true 
compatible.   The assemblers may be run off of a floppy disk drive or 
they may be copied onto a hard drive for execution.  DOS 2.0 or later 
is required.


1.4   ASSEMBLER PROCESSING

The  Macro  Assembler is a two-pass assembler. During the first pass, 
the source program is read to develop the symbol  table.  During  the 
second pass, the object file is created (assembled) with reference to 
the table developed in pass one. It is during the  second  pass  that 
the source program listing is also produced.

Each  source statement is processed completely before the next source 
statement is read. As each  statement  is  processed,  the  Assembler 
examines the label, operation code, and operand fields. The operation 
code table is scanned for a match with a known  opcode.   During  the 
processing  of  a  standard  operation  code  mnemonic,  the standard 
machine code is inserted  into  the  object  file.  If  an  Assembler 
directive is being processed, the proper action is taken.

Any  errors  that  are detected by the Assembler are displayed before 
the actual line containing the error is printed. If no source listing 
is  being  produced,  error  messages are still displayed to indicate 
that the assembly process did not proceed normally.
























                                 2



                                   Freeware Assemblers User's Manual


                              CHAPTER 2 
                   CODING ASSEMBLY LANGUAGE PROGRAMS


2.1   INTRODUCTION

Programs written in assembly language consist of a sequence of source 
statements.  Each  source  statement  consists of a sequence of ASCII 
characters ending with a carriage return.  Appendix A contains a list 
of the supported character set.


2.2   SOURCE  STATEMENT FORMAT

Each  source statement may include up to four fields: a label (or "*" 
for a comment line), an operation (instruction mnemonic or assembler 
directive), an operand, and a comment.


2.2.1   Label Field

The  label field occurs as the first field of a source statement. The 
label field can take one of the following forms:

1. An asterisk  (*)  as  the  first  character  in  the  label  field 
indicates  that  the  rest  of  the  source  statement  is a comment. 
Comments are ignored by the Assembler, and are printed on the  source 
listing only for the programmer's information.

2.  A  white space  character  (blank  or  tab) as the first character 
indicates that the label field is empty. The line has no label and is 
not a comment.

3.  A symbol character as the first character indicates that the line 
has a label. Symbol characters are the upper or lower case letters a- 
z,  digits  0-9,  and the special characters, period (.), dollar sign 
($), and underscore (_). Symbols consist of one to 15 characters, the 
first  of  which  must be alphabetic or the special characters period 
(.) or underscore (_).  All characters are significant and upper  and 
lower case letters are distinct.

A  symbol  may  occur  only once in the label field. If a symbol does 
occur more than once in a label field, then each  reference  to  that 
symbol will be flagged with an error.

With  the exception of some directives, a label is assigned the value 
of the program counter of the first byte of the instruction  or  data 
being  assembled. The value assigned to the label is absolute. Labels 
may optionally be ended with a colon (:).  If the colon is used it is 
not  part  of the label but merely acts to set the label off from the 
rest of the source line.   Thus  the  following  code  fragments  are 
equivalent:

     here:  deca
            bne here

                                 3


                                   Freeware Assemblers User's Manual


     here   deca
            bne here

A  label  may  appear  on a line by itself.  The assembler interprets 
this as set the value of the label equal to the current value of  the 
program counter.

The  symbol  table  has  room  for  at least 2000 symbols of length 8 
characters or less.  Additional characters up to 15  are  permissible 
at  the  expense of decreasing the maximum number of symbols possible 
in the table.


2.2.2   Operation Field

The operation field  occurs  after  the  label  field,  and  must  be 
preceded  by  at  least one white space character. The operation field 
must contain a legal opcode  mnemonic  or  an  assembler  directive.  
Upper  case  characters  in  this  field  are converted to lower case 
before being checked as a legal mnemonic.  Thus  'nop',  'NOP',  and 
'NoP'  are recognized as the same mnemonic. Entries in the operation 
field may be one of two types:

Opcode. These correspond directly to the  machine  instructions.  The 
operation  code  includes  any  register  name  associated  with  the 
instruction.  These register names must not  be  separated  from  the 
opcode  with  any  white space  characters.   Thus  'clra' means clear 
accumulator A, but 'clr a' means clear memory location identified  by 
the label 'a'.

Directive.  These  are special operation codes known to the Assembler 
which control the assembly process rather than being translated  into 
machine instructions.


2.2.3   Operand Field

The  operand  field's  interpretation is dependent on the contents of 
the operation field. The operand field, if required, must follow  the 
operation  field,  and  must  be  preceded by at least one white space 
character. The operand field may contain a symbol, an expression,  or 
a combination of symbols and expressions separated by commas.

The  operand  field  of  machine  instructions is used to specify the 
addressing mode of the instruction, as well as  the  operand  of  the 
instruction.   The  following  tables  summarize  the  operand  field 
formats for the various processor families. (NOTE:  in  these  tables 
parenthesis  "()"  signify  optional elements and angle brackets "<>" 
denote an expression is inserted.  These syntax elements are  present 
only  for clarification of the format and are not inserted as part of 
the actual source program.  All other characters are significant  and 
must be used when required.)




                                 4


                                   Freeware Assemblers User's Manual


2.2.3.1  M6800/6801 Operand Syntax

The format of the operand field for M6800/6801 instructions is:

     Operand Format           M6800/M6801 Addressing Mode
     --------------           ---------------------------
     no operand               accumulator and inherent
     <expression>             direct, extended, or relative
     #<expression>            immediate
     <expression>,X           indexed

Details of the M6800/6801 addressing modes may be found in Appendix B.


2.2.3.2  M6804/68HC Operand Syntax

For the M6804/68HC04, the following operand formats exist:

     Operand Format                M6804/68HC04 Addressing Mode
     --------------                ----------------------------
     no operand                    accumulator and inherent
     <expression>                  direct, extended, or relative
     #<expression>                 immediate
     <expression>                  bit set or clear
     <expression>,<expression>     bit test and branch
     [<x> or <y>]                  register indirect
     <expression>,#<expression>    move indirect

Details of the M6804/68HC04 addressing modes may be found in Appendix
B.


2.2.3.3  M6805/M68HC05 Operand Syntax

For the M6805/68HC05, the operand formats are:

     Operand Format                M6805/68HC05 Addressing Mode
     --------------                ----------------------------
     no operand                    accumulator and inherent
     <expression>                  direct, extended, or relative
     #<expression>                 immediate
     <expression>,X                indexed
     <expression>,<expression>     bit set or clear
     <expression>,<expression>,<expression>     bit test and branch

Details of the M6805/68HC05 addressing modes may be found in Appendix
B.


2.2.3.4  M6809 Operand Syntax

For the M6809, the following  operand formats are used:




                                 5


                                   Freeware Assemblers User's Manual


     Operand Format           M6809 Addressing Mode
     --------------           ---------------------
     no operand               accumulator and inherent
     <expression>             direct, extended, or relative
     #<expression>            immediate
     <expression>,X           indexed
     <<expression>            forced direct
     ><expression>            forced extended
     <expression>]            extended indirect
     <expression>,R           indexed
     <<expression>,R          forced 8-bit offset indexed
     ><expression>,R          forced 16-bit offset indexed
     [<expression>,R]         indexed indirect
     <[<expression>,R]        forced 8-bit offset indexed indirect
     >[<expression>,R]        forced 16-bit offset indexed indirect
     Q+                       auto increment by 1
     Q++                      auto increment by 2
     [Q++]                    auto increment indirect
     -Q                       auto decrement by
     --Q                      auto decrement by 2
     [--Q]                    auto decrement indirect
     W1,[W2,...,Wn]           immediate

where R is one of the registers PCR, S, U, X, or Y, and Q is one of
the registers S, U, X, or Y.   Wi  (i=1 to n) is one of the symbols A,
B, CC, D, DP, PC, S, U, X, or Y.

Details of the M6809 addressing modes may be found in Appendix B.


2.2.3.5  M68HC11 Operand Syntax

For the M68HC11, the following operand formats exist:

     Operand Format                M68HC11 Addressing Mode
     --------------                -----------------------
     no operand                    accumulator and inherent
     <expression>                  direct, extended, or relative
     #<expression>                 immediate
     <expression>,X                indexed with X register
     <expression>,Y                indexed with Y register
     <expression> <expression>     bit set or clear
     <expression> <expression> <expression>     bit test and branch

The  bit manipulation instruction operands are separated by spaces in 
this case since the HC11  allows  bit  manipulation  instructions  on 
indexed addresses.  Thus a ',X' or ',Y' may be added to the final two 
formats above to form the indexed effective address calculation.

Details of the M68HC11 addressing modes  may be found in  Appendix  B.
The operand fields of assembler directives are described in Chapter 4.


2.2.3.6  Expressions.   An  expression  is  a combination of symbols, 
constants, algebraic operators, and parentheses.  The  expression  is 
used to specify a value which is to be used as an operand.

                                6


                                   Freeware Assemblers User's Manual


Expressions  may  consist of symbols, constants, or the character '*' 
(denoting the current value of the program counter)  joined  together 
by one of the operators: + - * / % & | ^ .


2.2.3.7  Operators.  The operators are the same as in c:

     +    add
     -    subtract
     *    multiply
     /    divide
     %    remainder after division
     &    bitwise and
     |    bitwise or
     ^    bitwise exclusive or

Expressions are evaluated left to right and there is no provision for 
parenthesized expressions.  Arithmetic is carried out in signed  twos
complement integer precision (that's 16 bits on the IBM PC).


2.2.3.8  Symbols.   Each  symbol  is associated with a 16-bit integer 
value which is used in place of  the  symbol  during  the  expression 
evaluation.   The  asterisk  (*)  used  in  an expression as a symbol 
represents the current value of the location counter (the first  byte 
of a multi-byte instruction).


2.2.3.9  Constants.   Constants  represent quantities of data that do 
not vary in value during the execution of a program.   Constants  may 
be  presented  to  the  assembler  in  one  of five formats: decimal, 
hexadecimal, binary, or octal, or ASCII.   The  programmer  indicates 
the number format to the assembler with the following prefixes:

     $    HEX
     %    BINARY
     @    OCTAL
     '    ASCII

Unprefixed  constants  are  interpreted  as  decimal.   The assembler 
converts all constants to binary machine code and  are  displayed  in 
the assembly listing as hex.

A  decimal constant consists of a string of numeric digits. The value 
of a decimal constant must fall in the range 0-65535, inclusive.  The 
following example shows both valid and invalid decimal constants:

     VALID     INVALID   REASON INVALID
     -----     -------   --------------
     12        123456    more than 5 digits
     12345     12.3      invalid character

A  hexadecimal constant consists of a maximum of four characters from 
the set of digits (0-9) and the upper case alphabetic letters  (A-F), 
and is preceded by a dollar sign ($).  Hexadecimal constants must be


                                 7


                                   Freeware Assemblers User's Manual


in  the  range $0000 to $FFFF. The following example shows both valid 
and invalid hexadecimal constants:

     VALID     INVALID   REASON INVALID
     -----     -------   --------------
     $12       ABCD      no preceding "$"
     $ABCD     $G2A      invalid character
     $001F     $2F018    too many digits

A binary constant consists of a maximum of 16 ones or zeros  preceded 
by  a  percent  sign (%).  The following example shows both valid and 
invalid binary constants:

     VALID     INVALID             REASON INVALID
     -----     -------             --------------
     %00101    1010101             missing percent
     %1        %10011000101010111  too many digits
     %10100    %210101             invalid digit

An octal constant consists  of  a  maximum  of  six  numeric  digits, 
excluding  the  digits 8 and 9, preceded by a commercial at-sign (@). 
Octal constants must be in the ranges @0 to @177777.   The  following 
example shows both valid and invalid octal constants:

     VALID     INVALID   REASON INVALID
     -----     -------   --------------
     @17634    @2317234  too many digits
     @377      @277272   out of range
     @177600   @23914    invalid character

A  single  ASCII  character can be used as a constant in expressions. 
ASCII constants are preceded by a single quote  (').  Any  character, 
including the single quote, can be used as a character constant.  The 
following example shows both valid and invalid character constants:

     VALID     INVALID   REASON INVALID
     -----     -------   --------------
     '*        'VALID    too long

For the invalid case above the assembler will not indicate an  error. 
Rather it will assemble the first character and ignore the remainder.


2.2.4   Comment Field

The last field of an Assembler source statement is the comment field. 
This field is optional and is only printed on the source listing  for 
documentation  purposes.  The  comment  field  is  separated from the 
operand field (or from the operation field if no operand is required) 
by  at  least one white space character. The comment field can contain 
any printable ASCII characters.



                                 8



                                   Freeware Assemblers User's Manual


2.3   ASSEMBLER OUTPUT

The Assembler output includes  an  optional  listing  of  the  source 
program  and an object file which is in the Motorola S Record format. 
Details of the S Record format may  be  found  in  Appendix  E.   The 
Assembler  will normally suppress the printing of the source listing. 
This condition, as well as others,  can  be  overridden  via  options 
supplied on the command line that invoked the Assembler.

Each  line  of  the  listing  contains  a  reference line number, the 
address and bytes assembled, and the original source input line.   If 
an  input line causes more than 6 bytes to be output (e.g. a long FCC 
directive), additional bytes (up to  64)  are  listed  on  succeeding 
lines with no address preceding them.

The assembly listing may optionally contain a symbol table or a cross 
reference table of all symbols appearing in the  program.  These  are 
always  printed  at  the  end  of  the assembly listing if either the 
symbol table or cross reference table options (Paragraph 4.8) are  in 
effect. The symbol table contains the name of each symbol, along with 
its defined value. The cross reference  table  additionally  contains 
the  assembler-maintained  source  line  number of every reference to 
every symbol. The format of the cross reference  table  is  shown  in 
Appendix D.
































                                 9



                                   Freeware Assemblers User's Manual


                              CHAPTER 3
                        RUNNING THE ASSEMBLERS


3.1   ASSEMBLER INVOCATION

The  Motorola  Freeware Assembly programs are named as*.exe where '*' 
is any of 0, 1, 4, 5, 9, or 11 depending on  which  processor  family 
you  wish  to assemble code for.  For example, to generate M6800 code 
run the as0.exe program.  To generate M68HC05 code  run  the  as5.exe 
program,  and  so  forth.   To  run the assembler enter the following 
command line:

         as*   file1 (file2 . . . ) ( - option1 option2 . . . )

where file1, file2, etc are the names of the source files you wish to 
assemble.  The source filenames may have extensions but the assembler 
does not check for any particular extension ( however, do not use the
.S19 extension since that is the extension of the object file created
by the assembler.  Its creation would overwrite the source file when
it is written to the disk).

The options are one or more of the following:

     l    enables output listing
     no   disables output listing (default).
     cre  enables the cross reference table generation
     s    enables the symbol table generation
     c    enables cycle counting
     noc  disables cycle counting

The minus sign preceding the option should be separated from the last 
file  name  by  a  space.  These options may also be indicated to the 
assembler by the use of the OPT directive in the  source  file.   The 
OPT directive is described in Paragraph 4.8.

The  object  file  created  is  written  to  disk  and given the name 
'FILENAME.S19' where 'FILENAME' is the name of the first source  file 
specified  on  the command line.  Any errors and the optional listing 
(if specified) are displayed on the screen.  The listing and/or error 
messages  may be saved to a file for later examination or printing by 
append an i/o redirection command to the command line.  On the PC i/o 
redirection  is indicated with the greater-than ('>') symbol followed 
by any new or existing file name.

Command line examples:

The command line

         as5 myfile

would run the M6805/68HC05 assembler on  the  source  file  'myfile'.  
The object file would be written to 'myfile.s19' and any errors would 
appear on the screen.


                                 10



                                   Freeware Assemblers User's Manual


The command line

         as9 test.asm nexttest.s -l

would run the M6809 assembler on  the  source  files  'test.asm'  and 
'nexttest.s'.  The object file would be written to 'test.s19' and any 
errors and the assembly listing would appear on the screen.

The command line

         as9 test.asm nexttest.s -l cre s >test.lst

would run the M6809 assembler on  the  source  files  'test.asm'  and 
'nexttest.s'.   The  object  file  would be written to 'test.s19'.  A 
listing would be  created  followed  by  a  symbol  table  and  cross 
reference which would all be written to the file test.lst
.

3.2   ERROR MESSAGES

Error  diagnostic messages are placed in the listing file just before 
the line containing the error.  The format of the error line is:

             Line_number:   Description of error

                                  or

             Line_number:   Warning ---- Description of error

Errors in pass one cause cancellation of pass two.   Warning  do  not 
cause  cancellation  of  pass  two  but are indications of a possible 
problem.  Error messages are meant to be self-explanatory.

If more than one file is being assembled, the file name precedes  the 
error:

             File_name,Line_number:  Description of error

Some  errors  are classed as fatal and cause an immediate termination 
of the assembly.  Generally this happens when a temporary file cannot 
be created or is lost during assembly.















                                11



                                   Freeware Assemblers User's Manual


                              CHAPTER 4
                         ASSEMBLER DIRECTIVES


4.1   INTRODUCTION

The  Assembler  directives  are instructions to the Assembler, rather 
than instructions to be directly translated into  object  code.  This 
chapter  describes the directives that are recognized by the Freeware 
Assemblers. Detailed descriptions  of  each  directive  are  arranged 
alphabetically. The notations used in this chapter are:

  ( )  Parentheses denote an optional element.

  XYZ  The names of the directives are printed in capital letters.

  <  >  The  element names are printed in lower case and contained in 
angle brackets.  All elements outside of the angle brackets '<>' must 
be  specified as-is. For example, the syntactical element (<number>,) 
requires the comma to be specified if the optional  element  <number> 
is  selected.  The  following  elements  are  used  in the subsequent 
descriptions:


     <comment>      A statement's comment field
     <label>        A statement label
     <expression>   An Assembler expression
     <expr>         An Assembler expression
     <number>       A numeric constant
     <string>       A string of ASCII characters
     <delimiter>    A string delimiter
     <option>       An Assembler option
     <symbol>       An Assembler symbol
     <sym>          An Assembler symbol
     <sect>         A relocatable program section
     <reg list>     M6809 register list
     <reg exp>      M6809 register expression


In the following descriptions of the various directives, the  syntax, 
or  format,  of  the directive is given first.  This will be followed 
with the directive's description.

4.2   BSZ - BLOCK STORAGE OF ZEROS

                   (<label>) BSZ <expression> (<comment>)

The BSZ directive causes the Assembler to allocate a block of  bytes. 
Each  byte is assigned the initial value of zero. The number of bytes 
allocated is given by the expression in the  operand  field.  If  the 
expression  contains  symbols  that  are  either undefined or forward 
referenced (i.e. the definition occurs later on in the file),  or  if 
the expression has a value of zero, an error will be generated.



                                 12



                                   Freeware Assemblers User's Manual


4.3   EQU - EQUATE SYMBOL TO A VALUE

                   <label> EQU <expression> (<comment>)

The  EQU directive assigns the value of the expression in the operand 
field to the label. The EQU directive assigns a value other than  the 
program  counter to the label. The label cannot be redefined anywhere 
else in the program.   The  expression  cannot  contain  any  forward 
references or undefined symbols.  Equates with forward references are 
flagged with Phasing Errors.

4.4   FCB - FORM CONSTANT BYTE

         (<label>) FCB <expr>(,<expr>,...,<expr>) (<comment>)

The FCB directive may have one or more operands separated by  commas. 
The  value  of each operand is truncated to eight bits, and is stored 
in a single byte of the object program.  Multiple operands are stored 
in  successive  bytes.  The  operand  may  be  a  numeric constant, a 
character constant, a symbol, or an expression. If multiple  operands 
are  present,  one or more of them can be null (two adjacent commas), 
in which case a single  byte  of  zero  will  be  assigned  for  that 
operand. An error will occur if the upper eight bits of the evaluated 
operands' values are not all ones or all zeros.

4.5   FCC - FORM CONSTANT CHARACTER STRING

         (<label>) FCC <delimiter><string><delimiter> (<comment>)

The FCC directive is used to store  ASCII  strings  into  consecutive 
bytes  of  memory.   The  byte  storage begins at the current program 
counter.  The label is assigned to the first byte in the string.  Any 
of  the  printable  ASCII  characters can be contained in the string.  
The string is specified between two identical delimiters which can be 
any  printable  ASCII  character. The first non-blank character after 
the FCC directive is used as the delimiter.

Example:

     LABEL1    FCC  , ABC,

assembles ASCII ABC at location LABEL1


4.6 FDB - FORM DOUBLE BYTE CONSTANT

         (<label>) FDB <expr>(,<expr>,...,<expr>) (<comment>)

The FDB directive may have one or more operands separated by  commas. 
The  16-bit  value  corresponding  to each operand is stored into two 
consecutive bytes of the object program.  The storage begins  at  the 
current  program  counter.  The label is assigned to the first 16-bit 
value. Multiple operands are stored in successive bytes.  The operand 
may  be  a  numeric  constant,  a character constant, a symbol, or an 
expression. If multiple operands are present, one or more of them can

                                 13



                                   Freeware Assemblers User's Manual


be null (two adjacent commas), in which case two bytes of zeros  will 
be assigned for that operand.

4.7 FILL - FILL MEMORY

                   (<label>) FILL <expression>,<expression>

The  FILL  directive  causes  the  assembler to initialize an area of 
memory with a constant value.  The first expression signifies the one 
byte  value  to  be  placed  in  the memory and the second expression 
indicates the total number of successive  bytes  to  be  initialized.  
The  first  expression must evaluate to the range 0-255.  Expressions 
cannot contain forward references or undefined symbols.

4.8 OPT - ASSEMBLER OUTPUT OPTIONS

         OPT <option>(,<option>,...,<option>) (<comment>)

The OPT directive is used to control  the  format  of  the  Assembler 
output.  The options are specified in the operand field, separated by 
commas. All options have a default condition.  Some  options  can  be 
initialized from the command line that invoked the Assembler, however 
the options contained in the source file  take  precedence  over  any 
entered  on  the  command  line.  In  the following descriptions, the 
parenthetical inserts specify "DEFAULT", if the option is the default 
condition.  All options must be entered in lower case.

  c  -  Enable  cycle counting in the listing.  The total cycle count 
for that instruction will appear in the listing after  the  assembled 
bytes and before the source code.

  cre  -  Print  a  cross  reference  table  at the end of the source 
listing. This option, if used, must be  specified  before  the  first 
symbol  in  the  source  program is encountered.  The cross reference 
listing format may be found in Appendix D.

   l - Print the listing from this point on.  A  description  of  the 
listing format can be found in Appendix D.

   noc - (DEFAULT) Disable cycle counting in the listing.  If the "c" 
option was used previously in the program,  this  option  will  cause 
cycle counting to cease until the next "OPT c" statement.

  nol  -  (DEFAULT)  Do not print the listing from this point on.  An 
"OPT l" can re-enable listing at a later point in the program.

   s - Print symbol table at end of source listing.  The symbol table 
format can be found in Appendix D.


4.9 ORG - SET PROGRAM COUNTER TO ORIGIN

                   ORG <expression> (<comment>)

The  ORG directive changes the program counter to the value specified 
by the expression in the operand field. Subsequent statements are

                                 14



                                   Freeware Assemblers User's Manual


assembled into memory locations starting with the new program counter 
value.  If  no  ORG directive is encountered in a source program, the 
program counter is initialized to zero.  Expressions  cannot  contain 
forward references or undefined symbols.


4.10 PAGE - TOP OF PAGE

                   PAGE

The  PAGE  directive causes the Assembler to advance the paper to the 
top of the next page. If no source listing  is  being  produced,  the 
PAGE  directive  will have no effect. The directive is not printed on 
the source listing.


4.11 RMB - RESERVE MEMORY BYTES

                (<label>) RMB <expression> (<comment>)

The RMB directive causes the location counter to be advanced  by  the 
value of the expression in the operand field. This directive reserves 
a block of memory the length of which in bytes is equal to the  value 
of the expression. The block of memory reserved is not initialized to 
any given value. The expression cannot contain any forward references 
or  undefined  symbols.  This directive is commonly used to reserve a 
scratchpad or table area for later use.

4.12 ZMB - ZERO MEMORY BYTES  (same as BSZ)

                  (<label>) ZMB <expression> (<comment>)

The ZMB directive causes the Assembler to allocate a block of  bytes. 
Each  byte is assigned the initial value of zero. The number of bytes 
allocated is given by the expression in the  operand  field.  If  the 
expression  contains  symbols  that  are  either undefined or forward 
references, or if the expression has a value of zero, an  error  will 
be generated.



















                                 15



                                   Freeware Assemblers User's Manual


                               APPENDIX A
                              CHARACTER SET


The  character  set recognized by the Freeware Assemblers is a subset 
of ASCII. The ASCII code  is  shown  in  the  following  figure.  The 
following characters are recognized by the Assembler:

        1.  The upper case letters A through Z and lower case letters 
            a through z.

        2. The digits 0 through 9.

        3. Five arithmetic operators:   +, -, *, / and %   (remainder
           after division).

        4. Three logical operators:  &, |, and ^.

        5. The special symbol characters:  underscore (_), period (.),
           and dollar sign ($).  Only the underscore and period may be
           used as the first character of a symbol.

        6. The characters used as prefixes for constants and
           addressing modes:

               #    Immediate addressing
               $    Hexadecimal constant
               &    Decimal constant
               @    Octal constant
               %    Binary constant
               '    ASCII character constant

        7. The characters used as suffixes for constants and
           addressing modes:

               ,X   Indexed addressing
               ,PCR M6809 indexed addressing
               ,S   M6809 indexed addressing
               ,U   M6809 indexed addressing
               ,Y   M6809 and M68HC11 indexed addressing

        8. Three separator characters:  space, carriage return, and
           comma.

        9. The character "*" to indicate comments.  Comments may
           contain any printable characters from the ASCII set.

       10. The  special  symbol  backslash  "\"  to   indicate   line 
           continuation.   When  the  assembler  encounters  the line 
           continuation character it fetches the next line  and  adds 
           it  to  the end of the first line.  This continues until a 
           line is seen which doesn't end with a backslash  or  until 
           the   system   maximum  buffer  size  has  been  collected 
           (typically greater or equal to 256).


                                16



                                   Freeware Assemblers User's Manual


       11. For the M6809 Assembler,  the character  "<"  preceding an
           expression to  indicate  direct  addressing mode or  8-bit
           offset in indexed mode, and the character ">" preceding an
           expression to indicate extended addressing mode or  16-bit
           offset in indexed mode.

      12. For the M6809  Assembler,  the characters used to  indicate
          auto increment and auto decrement in the indexed mode:   +,
          ++, -, --.




                         ASCII CHARACTER CODES


           BITS 4 to 6 -- 0    1    2    3    4    5    6    7
           -----------    ------------------------------------- 

                     0    NUL  DLE  SP   0    @    P    `    p
                B    1    SOH  DC1  :    1    A    Q    a    q
                I    2    STX  DC2  !    2    B    R    b    r
                T    3    ETX  DC3  #    3    C    S    c    s
                S    4    EOT  DC4  $    4    D    T    d    t
                     5    ENQ  NAK  %    5    E    U    e    u
                0    6    ACK  SYN  &    6    F    V    f    v
                     7    BEL  ETB  '    7    G    W    g    w
                T    8    BS   CAN  (    8    H    X    h    x
                O    9    HT   EM   )    9    I    Y    i    y
                     A    LF   SUB  *    :    J    Z    j    z
                3    B    VT   ESC  +    ;    K    [    k    {
                     C    FF   FS   ,    <    L    \    l    ;
                     D    CR   GS   -    =    M    ]    m    }
                     E    SO   RS   .    >    N    ^    n    ~
                     F    S1   US   /    ?    O    _    o    DEL





















                                17



                                   Freeware Assemblers User's Manual


                              APPENDIX B
                           ADDRESSING MODES

B.1   M6800/M6801 ADDRESSING MODES.

INHERENT OR ACCUMULATOR ADDRESSING
The M6800 includes some instructions which require no operands. These 
instructions are self-contained and employ the inherent addressing or 
the accumulator addressing mode.


IMMEDIATE ADDRESSING
Immediate  addressing  refers  to  the  use  of  one  or two bytes of 
information that immediately follow the  operation  code  in  memory. 
Immediate addressing is indicated by preceding the operand field with 
the pound sign or number sign character (#). The expression following 
the  # will be assigned one or two bytes of storage, depending on the 
instruction.


RELATIVE ADDRESSING
Relative addressing is used by branch instructions. Branches can only 
be executed within the range -126 to +129 bytes relative to the first 
byte of the  branch  instruction.   For  this  mode,  the  programmer 
specifies  the branch address expression and places it in the operand 
field. The actual branch offset is calculated by  the  assembler  and 
put  into  the  second byte of the branch instruction.  The offset is 
the two's complement of the difference between the  location  of  the 
byte immediately following the branch instruction and the location of 
the destination of the branch.  Branches out of bounds are flagged as 
errors by the assembler.


INDEXED ADDRESSING
Indexed  addressing is relative to the index register. The address is 
calculated at the time of instruction execution by adding a  one-byte 
displacement  (in  the second byte of the instruction) to the current 
contents of the X register. Since no sign extension is  performed  on 
this  one-byte  displacement,  the offset cannot be negative. Indexed 
addressing  is  indicated  by  the  characters  ",X"  following   the 
expression  in the operand field. The special case of ",X", without a 
preceding expression, is treated as "0,X".


DIRECT AND EXTENDED ADDRESSING
Direct and extended addressing utilize one (direct) or two (extended) 
bytes  to  contain  the  address of the operand. Direct addressing is 
limited to the  first  256  bytes  of  memory.  Direct  and  extended 
addressing  are indicated by only having an expression in the operand 
field. Direct addressing will  be  used  by  the  Assembler  whenever 
possible.





                                18



                                   Freeware Assemblers User's Manual


B.2   M6804/M68HC04 ADDRESSING MODES.

INHERENT OR ACCUMULATOR ADDRESSING
The M6800 includes some instructions which require no operands. These 
instructions are self-contained and employ the inherent addressing or 
the accumulator addressing mode.


IMMEDIATE ADDRESSING
Immediate  addressing  refers  to  the use of one byte of information 
that immediately follows the  operation  code  in  memory.  Immediate 
addressing is indicated by preceding the operand field with the pound 
sign or number sign character (#). The  expression  following  the  # 
will be assigned one byte of storage.


RELATIVE ADDRESSING
Relative addressing is used by branch instructions. Branches can only 
be executed within the range -15 to +16 bytes relative to  the  first 
byte  of  the  branch  instruction.   For  this  mode, the programmer 
specifies the branch address expression and places it in the  operand 
field.  The  actual  branch offset is calculated by the assembler and 
put into the second byte of the branch instruction.   The  offset  is 
the  two's  complement  of the difference between the location of the 
byte immediately following the branch instruction and the location of 
the destination of the branch.  Branches out of bounds are flagged as 
errors by the assembler.


DIRECT AND EXTENDED ADDRESSING
Direct and extended addressing utilize byte to contain the address of 
the  operand.  Direct addressing is limited to the first 256 bytes of 
memory.  Extended addressing concatenates the four  least-significant 
bits  of  the  opcode  with  the  byte following the opcode to form a 
12-bit address. Direct and extended addressing are indicated by  only 
having an expression in the operand field.  Direct addressing will be 
used by the Assembler whenever possible.


SHORT DIRECT
Some opcodes allow 4 memory locations in data space  ram  ($80,  $81, 
$82,  and  $83  to  be  referenced as part of the opcode.  The opcode 
determines the data space RAM location, and the instruction  is  only 
one  byte.   The  X  and  Y  registers  are at locations $80 and $81, 
respectively.  An expression used with short direct  addressing  must 
not  be forward referenced (that is its definition must occur before, 
not after this point in the file) and must equate to the  range  $80- 
$83.


BIT SET AND CLEAR
In the bit set/clear addressing mode, the bit to be set or cleared is 
part of the opcode.  The byte  following  the  opcode  specifies  the 
direct  address  of  the byte which will have the bit set or cleared. 
Any bit in the  256 byte data space memory that can be written (with


                                19



                                   Freeware Assemblers User's Manual


the exception of the data direction registers) can be set or  cleared 
with these two byte instructions.


BIT TEST AND BRANCH
The  bit  test  and  branch  addressing  mode is a combination of the 
direct addressing and relative addressing.  The bit to be tested, and 
it  condition  (set  or  clear), is included in the opcode.  The data 
space address of the  byte  to  be  tested  is  in  the  single  byte 
immediately  following  the opcode byte and follows direct addressing 
rules.  The third byte is  sign  extended  by  the  processor  during 
execution  to  form the 12-bit relative address which is added to the 
program counter if the condition is true.  This allows branches based 
on  any  readable  bit in the data space.  The branch span is -125 to 
+130 from the opcode address.  The branch target address is  used  by 
the  programmer  to  signify  the  relative  offset  -- the assembler 
calculates the offset value.  Branches out of bounds are  flagged  as 
errors by the assembler.


REGISTER INDIRECT
In  the register indirect mode, the operand is at the address in data 
space pointed to by the contents of one of the indirect registers,  X 
or  Y.   The  particular indirect register is encoded in bit 4 of the 
opcode by the assembler.  The assembler operand syntax  for  register 
indirect is

                    [<X> or <Y>]


MOVE IMMEDIATE
The MVI (move immediate) instruction has its own format:

         mvi   <expression 1>,#<expression 2>

where  <expression  1>  is a direct address and <expression 2> is the 
data value to be written.


MISCELLANEOUS SYNTAX ISSUES
The registers in  the  6804/HC6804  are  memory  locations  and  have 
addresses assigned to them.  The assembler has predefined

           a = A = $FF
           b = B = $80
           c = C = $81

This  also  means  that  for the '04 assembler clr x is equivalent to 
clrx since x is both a register and a memory location.

The '04 series has separate program and data  spaces.   There  is  no 
program memory in the range $10-$7F.  Bytes assembled into that range 
will go into the data space.



                                20



                                   Freeware Assemblers User's Manual


B.3   M6805/68HC05 ADDRESSING MODES.

INHERENT OR ACCUMULATOR ADDRESSING
The M6805 includes some instructions which require no operands. These 
instructions  are  self-contained, and employ the inherent addressing 
or the accumulator addressing mode.


IMMEDIATE ADDRESSING
Immediate addressing refers to the use of  one  byte  of  information 
that  immediately  follows  the  operation  code in memory. Immediate 
addressing is indicated by preceding the operand field with the pound 
sign  or  number  sign  character (#). The expression following the # 
will be assigned one byte of storage.


RELATIVE ADDRESSING
Relative addressing is used by branch instructions. Branches can only 
be executed within the range -126 to +129 bytes relative to the first 
byte of  the  branch  instruction.  For  this  mode,  the  programmer 
specifies  the branch address expression and places it in the operand 
field. The actual branch offset is calculated by  the  assembler  and 
put  into  the  second byte of the branch instruction.  The offset is 
the two's complement of the difference between the  location  of  the 
byte immediately following the branch instruction and the location of 
the destination of the branch.  Branches out of bounds are flagged as 
errors by the assembler.


INDEXED ADDRESSING
Indexed  addressing is relative to the index register. The address is 
calculated at the time of instruction execution by adding a  one-  or 
two-byte  displacement to the current contents of the X register. The 
displacement immediately follows the operation code  in  memory.   If 
the  displacement  is zero, no offset is added to the index register.  
In this case, only the operation code resides in  memory.   Since  no 
sign  extension  is  performed on a one-byte displacement, the offset 
cannot be negative. Indexed addressing is indicated by the characters 
",X" following the expression in the operand field.  The special case 
of ",X", without a preceding expression, is treated  as  "0,X".  Some 
instructions do not allow a two-byte displacement.


DIRECT AND EXTENDED ADDRESSING
Direct and extended addressing utilize one (direct) or two (extended) 
bytes to contain the address of the  operand.  Direct  addressing  is 
limited  to  the  first  256  bytes  of  memory.  Direct and extended 
addressing are indicated by only having an expression in the  operand 
field.  Some  instructions  do not allow extended addressing.  Direct 
addressing will be used by the Macro Assembler whenever possible.


BIT SET OR CLEAR
The addressing mode used for this  type  of  instruction  is  direct, 
although the format of the operand field is different from the direct 
addressing mode described above. The operand takes the form

                                21



                                   Freeware Assemblers User's Manual


<expression 1>, <expression 2>. <expression 1> indicates which bit is 
to be set or cleared.  It must be an absolute expression in the range 
0-7. It is used in generating the operation code.  <expression 2>  is 
handled  as  a  direct  address,  as  described above.  Since the bit 
manipulation address is direct, only the first 256 locations  may  be 
operated on by bit manipulation operations.


BIT TEST AND BRANCH
This  combines  two addressing modes: direct and relative. The format 
of the operand is: <expression 1>, <expression  2>,  <expression  3>. 
<expression  1>  and <expression 2> are handled in the same manner as 
described above in "bit set or clear".  <expression  3>  is  used  to 
generate   a  relative  address,  as  described  above  in  "relative 
addressing".


B.4  M6809 ADDRESSING MODES.

INHERENT OR ACCUMULATOR ADDRESSING
The M6809 includes some instructions which require no operands. These 
instructions  are  self-contained, and employ the inherent addressing 
or the accumulator addressing mode.


IMMEDIATE ADDRESSING
Immediate addressing refers to  the  use  of  one  or  two  bytes  of 
information  that  immediately  follow  the operation code in memory. 
Immediate addressing is indicated by preceding the operand field with 
the  pound  sign  or  number  sign  (#)  -- i.e., #<expression>.  The 
expression following the # will be  assigned  one  or  two  bytes  of 
storage,  depending  on the instruction. All instructions referencing 
the accumulator "A" or "B", or the condition code register "CC", will 
generate  a one-byte immediate value. Also, immediate addressing used 
with the PSHS, PULS, PSHU, and PULU instructions generates a one-byte 
immediate  value.  Immediate  operands used in all other instructions 
generate a two-byte value.

The register list operand does not take the  form  #<expression>  but 
still  generates  one byte of immediate data. The form of the operand 
is:

                            R1,R2,...,Rn

where Ri (i=1 to n) is one of the symbols A, B, CC, D, DP, PC, S,  U, 
X  or  Y.  The  number  and  type  of  symbols vary, depending on the 
specific instruction.

For the instructions PSHS, PULS, PSHU, and PULU,  any  of  the  above 
register  names  may  be  included  in  the  register  list. The only 
restriction is that "U" cannot be specified with PSHU  or  PULU,  and 
"S"  cannot  be  specified  with PSHS or PULS. The one-byte immediate 
value assigned to the operand is calculated by the assembler  and  is 
determined  by the registers specified. Each register name causes the 
assembler to set a bit in the immediate byte as follows:


                                 22



                                   Freeware Assemblers User's Manual


          Register  Bit
          --------  ---

            PC      7
            U,S     6
            Y       5
            X       4
            DP      3
            B,D     2
            A,D     1
            CC      0


For the instructions EXG and TFR, exactly two of the  above  register 
names must be included in the register list. The other restriction is 
the size of the registers specified. For the EXG instruction, the two 
registers  must  be  the  same size. For the TFR instruction, the two 
registers must be the same  size,  or  the  first  can  be  a  16-bit 
register  and  the  second  an  8-bit register. In the case where the 
transfer is from a 16-bit register to an 8-bit  register,  the  least 
significant  8  bits  are transferred.  The 8-bit registers are A, B, 
CC, and DP.  The 16-bit registers are D, PC, S, U,  X,  and  Y.   The 
one-byte  immediate value assigned to the operand by the assembler is 
determined by the register names. The most significant four  bits  of 
the  immediate byte contain the value of the first register name; the 
least significant four bits contain the value of the second register, 
as shown by the following table:.


          Register  Value (hex)
          --------  -----------

             D          0
             X          1
             Y          2
             U          3
             S          4
             PC         5
             A          8
             B          9
             CC         A
             DP         B


RELATIVE  ADDRESSING
Relative  addressing  is  used  by branch instructions. There are two 
forms of the  branch  instruction.  The  short  branch  can  only  be 
executed  within  the  range -126 to +129 bytes relative to the first 
byte of  the  branch  instruction.  For  this  mode,  the  programmer 
specifies  the branch address expression and places it in the operand 
field. The actual branch offset is calculated by  the  assembler  and 
put  into  the second byte of the branch instruction. The long branch 
can  execute  in  the  full  range  of  addressing   from   0000-FFFF 
(hexadecimal)  because  a  two-  byte  offset  is  calculated  by the 
assembler and put into the operand field of the  branch  instruction.  
The  offset  is  the  two's  complement of the difference between the 
location of the byte immediately 

                                23



                                   Freeware Assemblers User's Manual


following the branch instruction and the location of the  destination 
of the branch.


DIRECT AND EXTENDED ADDRESSING
Direct and extended addressing utilize one (direct) or two (extended) 
bytes to contain the address of  the  operand.  Direct  and  extended 
addressing  are indicated by having only an expression in the operand 
field (i.e., <expression>). Direct addressing will be  used  whenever 
possible.

Regardless  of  the criteria described above, it is possible to force 
the Assembler to use the direct  addressing  mode  by  preceding  the 
operand with the "<" character. Similarly, extended addressing can be 
forced by preceding the operand with the ">"  character.   These  two 
operand forms are: <<expression> and ><expression>.


INDEXED ADDRESSING
Indexed  addressing  is  relative  to one of the index registers. The 
general form is <expression>,R. The address is calculated at the time 
of  instruction  execution by adding the value of <expression> to the 
current contents of the index register. The  other  general  form  is 
[<expression>,R].   In  this indirect form, the address is calculated 
at the time of instruction execution by first  adding  the  value  of 
<expression>  to the current contents of the index register, and then 
retrieving the two bytes from the calculated address  and  address+1. 
This  two-byte value is used as the effective address of the operand. 
The allowable forms of indexed addressing are  described  below.   In 
the  description  below, R refers to one of the index registers S, U, 
X, or Y.

The accumulator offset mode allows one  of  the  accumulators  to  be 
specified instead of an <expression>. Valid forms are:.

                   <acc>,R and [<acc>,R]

where  <acc>  is  one  of  the  accumulators  A,  B,  or D. This form 
generates a one-byte operand (post-byte only). When accumulator A  or 
B  is  specified,  sign extension occurs prior to adding the value in 
the accumulator to the index register.

The valid forms for the automatic increment/decrement mode are  shown 
below.  For each row, the three entries shown are equivalent.


               R+       ,R+      0,R+
               -R       ,-R      0,-R
               R++      ,R++     0,R++
               --R      ,--R     0,--R
               [R++]    ,R++]    [0,R++]
               [--R]    [,--R]   [0,--R]


In  this  form,  the only valid expression is 0. Like the accumulator 
offset mode, this form generates a one-byte operand (post-byte only).

                                24



                                   Freeware Assemblers User's Manual


The valid forms for the expression offset mode are:


               R       ,R     <expression>,R
               [R]     [,R]   [<expression>,R]
               <R      <,R    <<expression>,R
               <[R]    <[,R]  <[<expression>,R]
               >R      >,R    ><expression>,R
               >[R]    >[,R]  >[<expression>,R]


The  "<"  and  ">"  characters  force  an  8-   or   16-bit   offset, 
respectively, and are described below. If no expression is specified, 
or if an expression with a value  of  zero  is  specified,  only  the 
postbyte  of  the operand is generated. If an expression with a value 
in the range -16 to +15 is specified without indirection, a one- byte 
operand  is  generated which contains the expression's value, as well 
as the index register indicator. At execution time, the  expression's 
value  is  expanded to 16 bits with sign extension before being added 
to the index register.

All other forms will generate a post-byte, as well as either  a  one- 
or  two-byte  offset  which contains the value of the expression. The 
size of the offset  is  determined  by  the  type  and  size  of  the 
expression.  Expressions  with  values  in  the  range  -128  to +127 
generate an 8-bit offset.  All other cases will result  in  a  16-bit 
offset  being  generated.  In  the  case  where  an  8-bit  offset is 
generated, the value is expanded to 16 bits with  sign  extension  at 
execution time.

Regardless  of  the criteria described above, it is possible to force 
the Assembler to generate an 8-bit offset by  preceding  the  operand 
with  the  "<" character. Similarly, a 16-bit offset can be forced by 
preceding the operand with the ">" character.

If the relative address calculated is not in the range -128 to  +127, 
or  if  the  expression  references  a  symbol  that has not yet been 
defined, a two-byte offset is generated after the post-byte.  A  one- 
byte offset is generated if the relative address is in the range -128 
to +127.

Like the expression offset mode, a one-byte offset can be  forced  by 
preceding  the operand with a "<".  A ">" forces a two-byte offset. A 
byte overflow error is generated if a one-byte offset is forced  when 
the relative address is not in the range -12 8 to +127.

The extended indirect mode has the form:

                     [<expression>]

Although  extended  indirect  is  a logical extension of the extended 
addressing mode, this mode is implemented using an  encoding  of  the 
postbyte  under  the indexed addressing mode.  A post-byte and a two- 
byte offset which contains the value of the expression is generated.


                                25



                                   Freeware Assemblers User's Manual


B.5  M68HC11 ADDRESSING MODES.

PREBYTE
The number of combinations of instructions and addressing  modes  for 
the  68HC11  is  larger  than that possible to be encoded in an 8-bit 
word (256 combinations).  To expand the opcode map,  certain  opcodes 
($18,  $1A, and $CD) cause the processor to fetch the next address to 
find the actual instruction.  These opcodes are known as prebytes and 
are  inserted  automatically  by the assembler for those instructions 
that require it.l  In  general  the  instructions  contained  in  the 
alternate maps are those involving the Y register or addressing modes 
that involve the Y index register.   Thus  the  programmer  make  the 
tradeoff  between  the convenience of using the second index register 
and the additional time and code space used by the prebyte.


INHERENT OR ACCUMULATOR ADDRESSING
The M68HC11 includes some instructions  which  require  no  operands. 
These  instructions  are  self-contained,  and  employ  the  inherent 
addressing or the accumulator addressing mode.


IMMEDIATE ADDRESSING
Immediate addressing refers to the  use  of  one  or  more  bytes  of 
information  that  immediately  follow  the operation code in memory. 
Immediate addressing is indicated by preceding the operand field with 
the pound sign or number sign character (#). The expression following 
the # will be assigned one byte of storage.


RELATIVE ADDRESSING
Relative addressing is used by branch instructions. Branches can only 
be executed within the range -126 to +129 bytes relative to the first 
byte of  the  branch  instruction.  For  this  mode,  the  programmer 
specifies  the branch address expression and places it in the operand 
field. The actual branch offset is calculated by  the  assembler  and 
put  into  the  second byte of the branch instruction.  The offset is 
the two's complement of the difference between the  location  of  the 
byte immediately following the branch instruction and the location of 
the destination of the branch.  Branches out of bounds are flagged as 
errors by the assembler.


INDEXED ADDRESSING
Indexed  addressing  is  relative  one of the index registers X or Y.  
The address is calculated at the time  of  instruction  execution  by 
adding  a  one-byte  displacement  to  the  current contents of the X 
register. The displacement immediately follows the operation code  in 
memory.   If  the  displacement  is  zero,  zero  resides in the byte 
following the opcode. Since no  sign  extension  is  performed  on  a 
one-byte   displacement,  the  offset  cannot  be  negative.  Indexed 
addressing  is  indicated  by  the  characters  ",X"  following   the 
expression in the operand field.  The special case of ",X", without a 
preceding expression, is treated as "0,X".


                                26



                                   Freeware Assemblers User's Manual


DIRECT AND EXTENDED ADDRESSING
Direct and extended addressing utilize one (direct) or two (extended) 
bytes  to  contain  the  address of the operand. Direct addressing is 
limited to the first  256  bytes  of  memory.   Direct  and  extended 
addressing  are indicated by only having an expression in the operand 
field.  Direct addressing will be  used  by  the  Assembler  whenever 
possible.


BIT(S) SET OR CLEAR
The  addressing  mode  used  for  this type of instruction is direct, 
although the format of the operand field is different from the direct 
addressing   mode   described  above.  The  operand  takes  the  form 
<expression 1> <expression 2> where the two expressions are separated 
by  a blank.  <expression 1> signifies the operand address and may be 
either a direct or an indexed address.   When  the  address  mode  is 
indexed, <expression 1> is followed by ',R' where R is either X or Y. 
This allows bit  manipulation  instructions  to  operate  across  the 
complete  64K  address  map.   <expression  2> is the mask byte.  The 
bit(s)  to  be  set  or  cleared  are  indicated  by  ones   in   the 
corresponding location(s) in the mask byte.  The mask byte must be an 
expression in the range 0-255 and is encoded by the programmer.


BIT TEST AND BRANCH
This combines two addressing modes: direct or indexed  and  relative. 
The   format  of  the  operand  is:  <expression  1>  <expression  2> 
<expression  3>  where  the  expressions  are  separated  by  blanks. 
<expression 1> identifies the operand an may indicate either a direct 
or indexed  address.   Indexed  addresses  are  signified  with  ',R' 
following  the expression where R is either X or Y. <expression 2> is 
the mask byte.  The bit(s) to be set or cleared are indicated by ones 
in  the  corresponding  location(s)  in the mask byte.  The mask byte 
must be an expression in the  range  0-255  and  is  encoded  by  the 
programmer. <expression 3> is used to generate a relative address, as 
described above in "relative addressing".




















                                27



                                   Freeware Assemblers User's Manual


                               APPENDIX C
                            DIRECTIVE SUMMARY


A complete description of all directives appears in Chapter 4.


ASSEMBLY CONTROL

     ORG  Origin program counter

SYMBOL DEFINITION

     EQU  Assign permanent value

DATA DEFINITION/STORAGE ALLOCATION

     BSZ  Block storage of zero; single bytes

     FCB  Form constant byte

     FCC  Form constant character string

     FDB  Form constant double byte

     FILL Initialize a block of memory to a constant

     RMB  Reserve memory; single bytes

     ZMB  Zero Memory Bytes; same and BSZ


 LISTING CONTROL

     OPT c     Enable cycle counting

     OPT cre   Print cross reference table

     OPT l     Print source listing from this point

     OPT nol   Inhibit printing of source listing from this point

     OPT s     Print symbol table

     PAGE Print subsequent statements on top of next page











                                28



                                   Freeware Assemblers User's Manual


                              APPENDIX D
                        ASSEMBLER LISTING FORMAT


The Assembler listing has the following format:

    LINE#   ADDR  OBJECT CODE BYTES       [ # CYCLES]  SOURCE LINE

The LINE# is a 4 digit decimal number printed as a  reference.   This 
reference number is used in the cross reference.  The ADDR is the hex 
value of the address for the first byte of the object code  for  this 
instruction.   The OBJECT CODE BYTES are the assembled object code of 
the source line in hex.  If an source line causes more than  6  bytes 
to be output (e.g. a long FCC directive), additional bytes (up to 64) 
are listed on succeeding lines with no address preceding them.

The # CYCLES will only appear in the listing if the "c" option is  in 
effect.   It  is enclosed in brackets which helps distinguish it from 
the source listing.  The SOURCE LINE is reprinted  exactly  from  the 
source program, including labels.

The symbol table has the following format:

     SYMBOL    ADDR

The  symbol  is  taken  directly  from  the label field in the source 
program.  The  ADDR  is  the  hexadecimal  address  of  the  location 
referenced by the symbol.

The cross reference listing has the following format:

     SYMBOL   ADDR   *LOC1 LOC2 LOC3 ...

The  SYMBOL and ADDR are the same as above. The * indicates the start 
of the line reference numbers.  The LOCs are the decimal line numbers 
of the assembler listing where the label occurs.




















                                29



                                   Freeware Assemblers User's Manual


                              APPENDIX E
                         S-RECORD INFORMATION


E.1   INTRODUCTION

The  S-record  output  format encodes program and data object modules 
into a printable (ASCII) format.  This allows viewing of  the  object 
file  with  standard  tools  and  allows  display of the module while 
transferring from one computer to the next or during loads between  a 
host  and  target.  The S-record format also includes information for 
use in error checking to insure the integrity of data transfers.


E.2   S-RECORD CONTENT

S-Records are character strings made of several fields which identify 
the  record  type,  record  length,  memory  address,  code/data, and 
checksum.  Each byte of binary  data  is  encoded  as  a  2-character 
hexadecimal number: the first character representing the high-order 4 
bits, and the second the low-order 4 bits of the byte.

The 5 fields which comprise an S-record are:

      TYPE  RECORD LENGTH   ADDRESS   CODE/DATA  CHECKSUM

The fields are defined as follows:

     FIELD      CHARACTERS                   CONTENTS
     -----      ----------                   --------
     Type           2         S-record type - S1, S9, etc.

     Record         2         The count of the character pairs in the
     length                   record,  excluding  the type and record
                              length.

     Address      4, 6,       The 2-,  3-, or 4-byte address at which
                  or 8        the  data  field  is  to be loaded into
                              memory.

     Code/data    0-2n        From  0  to n bytes of executable code,
                              memory  loadable  data,  or descriptive
                              information.

     Checksum       2         The least significant byte of the one's
                              complement  of the  sum  of  the values
                              represented by the pairs of  characters
                              making up the  record length,  address,
                              and the code/data fields.

Each record may be terminated with a CR/LF/NULL.


E.3   S-RECORD TYPES

Eight types of s-records have been defined to accommodate various

                                30



                                   Freeware Assemblers User's Manual


encoding,  transportation,  and   decoding   needs.    The   Freeware 
assemblers use only two types, the S1 and S9:

     S1   A record containing code/data and the 2-byte
          address at which the code/data is to reside.

     S9   A termination record for a block of S1 records. The address
          field  may  optionally  contain  the  2-byte address of the
          instruction to  which control  is to  be  passed.   If  not
          specified,  the first entry point specification encountered
          in  the  object  module  input  will  be used.  There is no
          code/data field.

E.4   S-RECORD EXAMPLE

The following is a typical S-record module:

          S1130000285F245F2212226A000424290008237C2A
          S11300100002000800082629001853812341001813
          S113002041E900084E42234300182342000824A952
          S107003000144ED492
          S9030000FC

The module consists of four code/data records and an S9 termination
record.

The first S1 code/data record is explained as follows:

     S1   S-record type S1, indicating a code/data record to be
          loaded/verified at a 2-byte address.

     13   Hex 13 (decimal 19), indicating 19 character pairs,
          representing 19 bytes of  binary data, follow.

     00   Four-character  2-byte  address  field:   hex address  0000,
          indicates location where the following data is to be loaded.

     The next  16 character pairs are the  ASCII  bytes of the actual
     program code/data

     2A   Checksum of the first S1 record.

The  second  and  third  S1  code/data  records each also contain $13 
character  pairs  and  are  ended  with  checksums.   The  fourth  S1 
code/data record contains 7 character pairs.

The S9 termination record is explained as follows:

     S9   S-record type S9, indicating a termination record.

     03   Hex 03, indicating three character pairs (3 bytes) to
          follow.

     00   Four character 2-byte address field, zeroes.
     00

     FC   Checksum of  S9 record.

                                31
